Intelligent system for safe electricity use

Intelligent Safe Electrical System

Led by CHENNUO ELECTRIC, along with postdoctoral researchers from Harbin Institute of Technology and the Chinese People's Liberation Army in electrical automation, this team, together with experts from the electrical industry, has developed and continuously improved a new active smart electrical safety system over several years. This system is primarily aimed at effectively preventing and protecting against accidents caused by electrical fires and electrical shocks due to aging electrical lines and insulation failures in low-voltage power supply networks.

Feature
1

No injury: When a person accidentally touches a wire at the output terminal of the device with one hand, the current flowing through the body is less than the specified safe current of 10 mA (the factory setting is <1 mA; this value may vary with line conditions and different load characteristics after connecting the circuit and load). This allows the person to quickly disengage from the power source, preventing injuries.

2

No fire: When the insulation of the power supply line and load devices controlled by the equipment is damaged, causing a metallic grounding short circuit, the system can effectively suppress arcing sparks and avoid electrical fire incidents.

3

No leakage: If any phase of the output line of the device experiences insulation damage and forms a grounding short circuit, it will not result in leakage current, thus preventing power outages in the grid and ensuring continuous, safe, and reliable power supply.

4

Real-time monitoring: When there is insulation damage and a short circuit to the ground line on the output line or load, the device can monitor the insulation resistance value in real time, ensuring continuous power supply and triggering an alarm based on preset values.

5

Multiple protections: The device features overload, overvoltage, undervoltage, overheating, leakage, and short circuit protection. If the measured values of the above parameters exceed the set thresholds, the device will provide corresponding alarm notifications and disconnect the power output to protect the circuit.

Parameter
Electrical parameters Working environment
Product model TDAQD Temperature range -20°C-60°C
Rated voltage AC380V, frequency 50Hz~60Hz Relative humidity <90RH%
Output voltage AC380V士5% Barometric pressure range 86KPa-106kPa
Other parameters 100KVA EXAMPLE

Endured current by a single hand touching at the contact point: <1 mA
Current of a single phase wire in a metallic grounding short circuit: <3 mA
Note: Testing environment without connected lines and loads.
Endured current by a single hand touching at the contact point: <10 mA
Current of a single phase wire in a metallic grounding short circuit: <30 mA
Note: 500 meters of line with a standard load.


Functional parameters for security protection

4 dimensions of security protection

Overcurrent (overload) protection to capacity 120KVA example.

Current end Current end
Current value Power supply protection mode Alarm mode Temperature value Power supply protection mode Alarm mode
150A ≥ current Normal operation Temperature sensor open circuit 1.2 Normal operation
180A≥current>150A Power off for 1 hour delay Continuous alarm for 30S Temperature sensor open circuit 1.23 Power off immediately Continuous alarm for 30S
240A≥current>180A Power off for 120S delay 150°C≥ temperature ≥ 90°C Power supply normally, turn on the exhaust fan
current>240A Power off for 5S delay Temperature> 150°CC Power supply normally, turn on the exhaust fan Continuous alarm for 30S
Current end Resistor end
Voltage value Power supply protection mode Alarm mode Insulation resistance value Power supply protection mode Alarm mode
Phase voltage> 259V Power off immediately Continuous alarm for 30S Phase A/phaseB phase C/ phase N zero Normal operation (under the safe electric power supply mode) The fault light is on, and there is no alarm
Phase voltage< 190V Power off immediately Any insulation resistance to the ground ≤20kΩ Immediate power off (under mains power supply) Continuous alarm for 30S


Working Principle: The system uses a special switching device to electrically dampen the output lines with the mains electricity lines, incorporating insulation monitoring circuits, electrical monitoring circuits, and more. Combined with the IT distribution method, this prevents the formation of an electrical circuit during a short circuit between the line and ground or when a person touches the line, avoiding the risk of arcing sparks. Additionally, the current from the human body to ground is controlled to stay within safe limits, preventing harm to individuals.

System Composition: This safety power supply solution integrates advanced microelectronic technology, power electronics technology, measurement and control technology, signal processing technology, Internet of Things (IoT) information technology, and cloud computing technology.


System Functions:Stability: Harmonic control, stable voltage output, and protection for application devices. Monitoring: Online monitoring of insulation resistance, voltage, current, temperature, and other operational states. Alarm: Alarms for protective functions and abnormal operations (without tripping). Query: Historical records of electricity usage curves (operation records, fault records). Communication: Enables remote monitoring and control via mobile and PC platforms.