ZW7A-30KV(40.5KV) Outdoor High Voltage Vacuum Circuit Breaker
This product is suitable for a 30KV(40.5KV), 50HZ three-phase distribution system and can effectively handle load switching currents, overload currents, and short-circuit currents. Additionally, it can serve as the main incoming switch for medium-voltage SVG-enabled power stations, suitable for locations below 2000 meters in altitude, with a spacing of 710mm, and supports custom dimensions to meet installation requirements above 4500 meters.
Product Mainly composed of an integrated pole, current transformer, operating mechanism, and enclosure.
Product uses vacuum as both the insulating medium and arc-extinguishing medium, making it an ideal product to replace DW oil circuit breakers.
The dimensions are reduced by 260mm compared, making it suitable for installation in spaces with limited positions.
Tech. parameters | Unit | data | ||
Rated voltage | KV | 40.5 | ||
Rated insulation level | 1min power frequency withstand voltage | Dry test | KV | 95 |
(Effective values) | Wet test | KV | 80 | |
Lightning impulse withstand voltage (peak) | KV | 185 | ||
Rated current | A | 1250/1600/2000 | ||
Rated short-circuit breaking current | KA | 20/25/31.5/40 | ||
Rated sequence of operations | break-0.3s-make and break-180s-make and break | |||
Rated capacitor bank breaking current | A | 400 | ||
Rated breaking times of short-circuit breaking current | times | 30 | ||
Rated short-circuit closing current (peak) | kA | 50/63/80/100 | ||
Rated peak withstand current | kA | 50/63/80 | ||
Rated short-time withstand current | kA | 20/25/31.5/40 | ||
Rated short-circuit duration | S | 4 | ||
Total breaking time | s | ≤0.08 | ||
Mechanical life | times | 20000 | ||
Rated operating voltage and rated voltage of auxiliary circuit | V | AC, DC 220, 110 | ||
Clearance between open contacts | mm | 22±2 | ||
Contact contact stroke | mm | 4±1 | ||
Average breaking speed | m/s | 1.7±0.2 | ||
Average making speed | m/s | 0.7±0.2 | ||
Contacts closing bounce duration | ms | ≤3 | ||
The three phases non-synchronism | ms | ≤2 | ||
Closing time | ms | ≤150 | ||
Opening time | ms | ≤60 | ||
The DC resistance of each phase circuit | mΩ | ≤100 |
Environmental conditions:
1.Ambient air temperature: +60℃ to -30℃
2.Altitude not exceeding 2000m
3.Wind pressure not exceeding 700Pa (equivalent to wind speed of 34m/s)
4.No frequent severe movements
5.Air pollution level: Grade III
LW36-30kv(40.5kv) series outdoor sulfur hexafluoride circuit breaker (SF6)
The LW36-35kv(40.5kv)/1250A-2000A high-voltage outdoor SF6 ...
See MoreZW32 Outdoor Vacuum Circuit Breaker
The device is an intelligent complete set of equipment ...
See MoreZW32-10kV(12kV) Pole-Mounted Outdoor Vacuum Circuit Breaker
ZW32-10kV(12kV) Pole-Mounted Outdoor Vacuum Circuit Breaker ...
See MoreZW32-10kv(12kv) Outdoor Vacuum Circuit Breaker
ZW32-12 Outdoor Vacuum Circuit Breaker combines a vacuum ...
See MoreZW32-10kV(12kV) Outdoor Pole-Mounted Vacuum Circuit Breaker
ZW32 combines a vacuum circuit breaker, feeder terminal, ...
See MoreZW32-10kV(12kV) Capacitor-Powered Insulation Column Circuit Breaker
This fully integrated circuit breaker combines the circuit ...
See MoreZW7-30kv(40.5kv) Outdoor High Voltage Vacuum Circuit Breaker
This product is suitable for a 30KV(40.5KV), 50HZ ...
See MoreZW7B-30kV(40.5kV) Outdoor Vacuum Circuit Breaker
This series of outdoor high-voltage vacuum circuit breakers ...
See MoreProduct Search
Here you can choose products online and find the products you want more quickly and accurately.
Customized Consultation
If you want to customize a product, please contact us, and our team is more than happy to assist you.
Product Procurement
If you want to purchase a product, please contact us and we will provide you with product information and a quotation.
Tel:+86 15538537280
Email:lycnelectric@163.com
Add:No. 9 Duyu Street, Luolong District, Luoyang City, Henan Province