Home - Products Center - Vacuum Circuit Breaker - Outdoor Vacuum Circuit Breaker - ZW7-40.5 Outdoor High Voltage Vacuum Circuit Breaker
Back
ZW7-40.5 Outdoor High Voltage Vacuum Circuit Breaker
ZW7-40.5 Outdoor High Voltage Vacuum Circuit Breaker

ZW7-40.5 Outdoor High Voltage Vacuum Circuit Breaker

This series of outdoor high-voltage vacuum circuit breakers has the advantages of safe and reliable performance, easy maintenance and long maintenance cycle. Due to the use of new insulating materials, there is no condensation on the outer side of the orphan extinguishing and the inner wall of the porcelain sleeve. The transformer is placed in the overall structure of the mechanism box or outside the box, which is convenient for installation. It also avoids oil and gas leakage and toxicity problems with other switches. Because the dynamic and static contacts of this circuit breaker are sealed in a vacuum interrupting chamber, using vacuum as an insulating medium and an arc extinguishing medium, it has a series of advantages that other types of switches cannot match. Therefore, this product is an ideal product to replace DW multi-oil circuit breaker. The mechanism of the operating mechanism box of this product in the middle of the circuit breaker is a mid-mounted high-voltage vacuum circuit breaker, which is 260mm smaller than the original circuit breaker, and is suitable for installation in places with less space and location.

Feature
1

The product is suitable for 40.5KV, 50HZ, three-phase power distribution system, as a load distribution current, overload current and short circuit current. It can also be used in the circuit of high-voltage SVG energy storage power station as the main inlet switch.

2

The spacing is 710 mm below 2,000 meters above sea level.

3

It can be installed at an altitude of more than 4500 meters, and the dimensions can be customized.

Parameter

Projects unit data
Rated voltage KV 40.5
Rated insulation level
1min power frequency withstand voltage Dry test KV 95
(RMS) Wet test KV 80
Lightning impulse withstand voltage (peak) KV 185
Current rating A 1250/1600/2000
Rated short-circuit interrupting current KA 20/25/31.5/40
Rated sequence of operations min-0.3s-combine-180s-combine
Rated capacitor bank breaking current A 400
Rated number of short-circuit breaking current interruptions Times 30
Rated short-circuit closing current (peak) KA 50/63/80/100
Rated peak withstand current KA 50/63/80
Rated short-time withstand current KA 20/25/31.5/40
Rated short-circuit duration S 4
Full breaking time S ≤0.08
Mechanical life times 20000
Rated operating voltage and rated voltage of auxiliary circuit V AC, DC 220, 110
Contact opening distance mm 22±2
Contact contact stroke mm 4±1
Average opening speed m/s 1.7±0.2
Average closing speed m/s 0.7±0.2
Contact closing bounce time ms ≤3
The synchronicity of the time difference between the three phases (minutes). ms ≤2
Closing time ms ≤150
Opening time ms ≤60
The DC power is strong in each phase circuit (mΩ) ≤100