Home - Products Center - Vacuum Circuit Breaker - Outdoor Vacuum Circuit Breaker - ZW32-12 Capacitor-Powered Insulation Column Circuit Breaker
Back
ZW32-12 Outdoor Pole-Mounted Vacuum Circuit Breaker
ZW32-12 Outdoor Pole-Mounted Vacuum Circuit Breaker

ZW32-12 Capacitor-Powered Insulation Column Circuit Breaker

Fully integrated circuit breaker body, feeder terminal FTU, power PT, and connection cable, and the deep integration of primary and secondary equipment is in place in one step, which solves the problems of remote signal jitter and terminal line loss collection in the distribution network; It realizes the functional requirements of distribution network segmented line loss management, in-situ feeder automation, single-phase grounding fault detection, factory pre-installation, plug and play, etc. Functional features: It has adaptive in-situ feeder automation, and realizes in-situ line selection, section positioning and isolation of single-phase grounding faults through control logic such as short-circuit or grounding fault detection technology, pressure-free switching, and adaptive delay call closing of fault paths; Cooperate with the secondary closing of the substation to realize the automatic isolation of permanent faults in situ and the restoration of power supply in the upstream area of the fault. Overall requirements: The new electronic sensor is deeply integrated with the column circuit breaker, improves the reliability of equipment operation, facilitates on-site operation and maintenance, meets the functional requirements of local feeder automation, and realizes equipment interconnection, state awareness, resource utilization, and intelligent decision-making functions.

Feature
1

Safe and reliable: light weight (85kg) to avoid the risk of accidents after installation, reduce the primary auxiliary equipment, reduce the risk of equipment failure, and eliminate the potential safety hazards of remote control caused by automation.

2

Operation function: realize the selective tripping of the short-circuit fault of the overhead line of the distribution network (multi-level precise differential coordination), realize the selective automatic isolation of the single-phase grounding fault of the overhead line of the distribution network (differential coordination), and solve the line loss assessment problem of the overhead line of the distribution network.

3

Product innovation: the use of high-precision, wide-range electronic sensor to replace the traditional electromagnetic transformer, to achieve measurement/protection/monitoring three-in-one compatibility, sensor and body pole integral sealing process, to achieve deep integration, power mode to solve the power supply PT, modular, standardized design, support hot swap, easy installation.

4

High degree of intelligence: the equipment does not depend on the master station, and when the line fails, it can accurately and quickly isolate the smallest fault area of the short circuit or single-phase grounding fault; the terminal can independently judge the short-circuit or single-phase grounding fault by itself and issue isolation instructions.

Parameter

The name of the parameter Unit Parameter value
Rated voltage KV 10
Rated cable charging breaking current A 25
Current rating A 630/1250
Rated short-circuit interrupting current KA 20/25
Rated peak withstand current (peak) KA 50/63
The frontal point is resistant to current for a short time KA 20/25
Rated short-circuit closing current (peak) KA 50/63
Mechanical life times 20000
Rated number of short-circuit breaking current interruptions times 30
Power frequency withstand voltage (1min) :(wet) (dry) interphase, ground/fracture KV 42/48
Withstand voltage (peak) of lightning impulse interphase, to ground/fracture KV 75/85
Voltage sensors
The name of the parameter numeric value
Rated conversion ratio Phase: 600A/1V, Zero Sequence: 20A/0.2V
Accuracy (including 15m cable) Phase: protection 5P10 level, metering 0.5S level 3-in-1 compatible Zero sequence: <1% (1%-120%ln, protection 10P10 level
How it works Low power consumption electromagnetic type
Temperature range -40℃-70℃
Load impedance Not less than 20kΩ

Current sensors

The name of the parameter numeric value
Rated conversion ratio Phase voltage: (10kV/ √3)/(3.25V/ √3), zero sequence (10kV/ √3)/(6.5V/ √3)
Accuracy (including 15m cable) Phase voltage: 0.5/3P level, zero sequence voltage: 3P
How it works Capacitor voltage divider
Temperature range -40℃-70℃
Load impedance 10pC,14.4kV
Insulation resistance when combined with a switch (switch opposite) ≥25MΩ
Load impedance The input impedance of the terminal > 10MΩ, and the input impedance of the distribution line loss acquisition module > 10MΩ

Current sensors

The name of the parameter numeric value
Rated conversion ratio Phase voltage: (10kV/ √3)/(3.25V/ √3), zero sequence (10kV/ √3)/(6.5V/ √3)
Accuracy (including 15m cable) Phase voltage: 0.5/3P level, zero sequence voltage: 3P
How it works Capacitor voltage divider
Temperature range -40℃-70℃
Load impedance 10pC,14.4kV
Insulation resistance when combined with a switch (switch opposite) ≥25MΩ
Load impedance The input impedance of the terminal > 10MΩ, and the input impedance of the distribution line loss acquisition module > 10MΩ