Home - Products Center - High and Low Voltage Complete Sets - High-voltage Distribution Cabinet - KYN28A-12 Indoor Withdrawable High-Voltage Switchgear
Back
KYN28A-12 Indoor Metal-enclosed Armoured Withdrawable Switchgear
KYN28A-12 Indoor Metal-enclosed Armoured Withdrawable Switchgear
KYN28A-12 Indoor Metal-enclosed Armoured Withdrawable Switchgear
KYN28A-12 Indoor Metal-enclosed Armoured Withdrawable Switchgear

KYN28A-12 Indoor Withdrawable High-Voltage Switchgear

KYN28A(GZS1)-12 armored withdrawable AC metal-enclosed switchgear is a complete set of indoor power distribution device with a rated voltage of 3.6~12KV three-phase AC 50HZ.It is used for power transmission in power plants, power systems and substations of industrial and mining enterprises, and can also be used for frequent start-up of high-voltage motors. This switchgear can meet the requirements of GB3906, DL404, IEC-298 and other standards, and has the "five prevention" functions such as preventing misoperation of circuit breakers, preventing load-bearing push-pull trolleys, preventing live closing grounding switches, preventing grounding switches from transmitting power when they are grounded and preventing them from accidentally entering the live interval.

Feature
1

The switch cabinet is composed of two parts: a fixed cabinet and a retractable part (hand car).

2

The cabinet shell and the partition of each functional unit are bolted with aluminum-zinc steel plate.

3

The enclosure protection level of the switch cabinet reaches IP4X, and the protection level of each compartment after opening the door is IP2X.

4

This switch cabinet can be equipped with VS1 (ZN63A) or according to the user's requirements to choose the specified model vacuum circuit breaker hand car.

5

The switch cabinet is reliable and wall-mounted.

6

Since the installation, commissioning and maintenance of the control cabinet can be carried out in front of the cabinet, it can be installed back to back in a double arrangement or against the wall.

Parameter

Number   Projects  
Unit Data
1 Rated voltage KV 3.6/7.2/12
2 Current rating A 630.1250,1600.2000.2500,3150.4000
3 Rated frequency Hz 50-60
4 Rated short-circuit interrupting current KA 20,25,31.5,40,50
5 Rated dynamic and stable current (peak) KA 50,63,80,100,125
6 Thermal Stability Current (4s) KA 20,25,31.5,40,50
7 Insulation level: power frequency/lightning shock kv 42/75
8 Ingress protection IP4X
9 Configure the circuit breaker ZN63A(VS1)、VD4、VEP、EV12etc
10 Operating mechanism Permanent magnet mechanism, spring mechanism
11 Operate the power supply V DC:110,220;AC:110,220
12 Dimensions (WxDxH) mm 800(650,1000)×1500(1700)x2300
13 weight Kg 800
Environmental conditions of use
  1. The ambient air temperature is not higher than +40°C and not lower than -10°C. The average temperature over a 24h period does not exceed +35°C.
  2. The daily average relative humidity of the surrounding environment shall not exceed 95%, and the monthly average relative humidity shall not exceed 90%. The daily average water vapor pressure shall not exceed 2.2 kP, and the monthly average water vapor pressure shall not exceed 1.8 kP.
  3. The altitude of the place of use shall not exceed 2000m.
  4. The maximum seismic intensity does not exceed 8 degrees. 5. The switch cabinet should be installed in an indoor place without fire, explosion hazard, serious pollution, chemical corrosive gas and violent vibration. Severe design under severe conditions meets the requirements of the class.
  6. In areas with hot and humid temperature fluctuations, there will be the possibility of condensation in the switch cabinet, and the condensation controller and heater can be configured as needed to make the environment in the cabinet in an automatic control state to prevent the equipment from being damp and condensing
  7. If the user has special requirements, please negotiate with our company.

Key features:
  1. The cabinet structure is assembled by multiple bendings of aluminum-zinc plate.
  2. All operations are carried out with the cabinet door closed.
  3. High protection level, which can prevent the invasion of debris and insect pests.
  4. Simple and effective "five prevention" locking to prevent misoperation.
  5. VS1 (ZN63A) can be used or the specified type vacuum circuit breaker can be selected according to user requirements.
  6. It is simple to replace the circuit breaker and the handcart has good interchangeability.
  7. The cabinet body is reliably installed on the wall, maintained in front of the cabinet, and reduced the floor space.
  8. The cable room has sufficient space and can be connected to multiple cables.
  9. The quick grounding switch is used for grounding and circuit short-circuit.
  10. Heaters can be installed in circuit breaker room, relay room and cable room according to user requirements to prevent condensation and corrosion.
  11. The circuit breaker room and cable room can be equipped with lighting devices according to user requirements to facilitate maintenance and overhaul.

Related Products
Service
WeChat

WeChat

WeChat

WeChat

Copyright © 2024 Chennuo Electric Powered by:ShanXian Sitexml

Home

Tel

Contact

Top